- Go to the contents area
- Go to the contents area
Control System
Control System
- Designing and integration control systems for a wide range of applications for all types of compressors as well as other packaged machinery.
- All cubicles, housings and panels are assembled and tested according to international standard codes and project specifications.
- All Control systems are integrated according to project specifications and required international codes.
- Executing the whole process of control system design, material selection, programing the control logic and the integration of PLC.
- Control system and instrumentation can be enhanced by integrating Safety Integration Level (SIL) and system redundancy.
- Suitable for use in harsh and hazardous environment by that is in conformance to international standard codes.
Applications
- Anti-Surge Control panels fully integrated
- Chiller system control panels
- Centrifugal, Screw and Reciprocating compressor
control panels and monitoring system
- Explosion proof panels
- Purged control panels
- Monitoring and supervisory control systems
- Redundant system
- Gas dryer and Air dryer package panels and monitoring system
- Pressure, temperature, level, flow, transmitters and gas detectors
Control System Reference Applications / Specifications
Unit Control Panel (Based on PLC)
- Application : Oil Free Rotary Screw Compressors for Offshore Platform
- UCP Comprised of :
- - Allen-Bradley Control Logix
- - Redundancy : CPU, Power Supply and Communication
- - Communications : Interface via MODBUS RTU with ICSS
- - I.S barriers for connecting with I.S type field instruments have been provided
- - HMI 12'1 colored TFT LCP
- - Enclosure ;
* 800L x 800D x 2100H mm including plinth/base 100mm
* Sheet steel with painting, IP54 for indoor
* free standing, front accessible only
- Features
- - Capacity load/unload controls
- - Monitoring/surveillance and safeguarding during operation
Local Control Panel (Based on PLC)
- Application : Oil Free Reciprocating Air Compressors of offshore fixed platform
- LCP Comprised of :
- - Siemens S7-300 system platform
- - Communications : interface via MODBUS RTU over RS-485 with DCS
- - Signal lamps, switches to interface with operator furnished on enclosure
door instead of HMI
- - Enclosure ;
- - 730L x 730D x 465H mm
- - aluminum alloyed (seawater resistant according to EN 13195-1) with painting
- - ATEX Ex ‘d’ flame proof approved, IP66
- Features
- - Capacity load/unload controls
- - Monitoring/surveillance and safeguarding during operation
- Application : Closed Cooling for Offshore Fixed Platform
- LCP Comprised of :
- - Siemens S7-300 system platform
- - Communications : interface via MODBUS RTU over RS-485 with DCS.
- - Signal lamps, switches to interface with operator furnished on enclosure
door instead of HMI
- - Enclosure ;
- - 730L x 730D x 465H mm
- - aluminum alloyed (seawater resistant according to EN 13195-1) with painting
- - ATEX Ex ‘d’ fame proof approved, IP66
- Features
- - Fan and Circulation Pump Control
- - Monitoring/surveillance and safeguarding during operation
Unit Control Panel (Based on PLC)
- Application : Oil Free Rotary Screw Compressors for onshore Gas Plant
- UCP Comprised of :
- - Siemens S7-400H platform and ET200M remote distributed system
- - Redundancy : CPU, Power Supply, Communication and I/O modules
- - Communications : interface via PROFINET among four(4) nos. UCPs and via
MODBUS TCP/IP with DCS
- - HMI 12.1” colored TFT LCP
- - Enclosure ;
- - 800L x 800D x 2100H mm including plinth/base 100mm
- - Sheet steel with painting, IP54 for indoor
- - free standing, front and rear accessible through doors
- Features
- - Capacity load/unload controls
- - Monitoring/surveillance and safeguarding during operation
- - Time synchronization of PLC via NTP has been provided
- - Sequence control by Lead/Lag selection
- - Machine monitoring and protection through input of GE-Bently Nevada’s
Seismic transmitters
Unit Control Panel (Based on PLC)
- Application : Portable Water Heating System (Hot Water Calorifier) for Offshore Platform
- UCP Comprised of :
- - Allen-Bradley Control Logix
- - Redundancy : CPU, Power Supply and Communication
- - Communications : interface via MODBUS RTU with ICSS.
- - Signal lamps and actuated switches/ buttons have been furnished
instead of HMI
- - Enclosure ;
* 800L x 300D x 1200H mm, St.st. 316L without painting
* Wall mounting, front accessible only
* ATEX Ex ‘e’ approved enclosure
- Features
- - Electric Heaters control
- - Monitoring/surveillance and safeguarding during operation
- - Declaration of Conformity (DOC) certification suitable for used in
ZONE 2 hazardous location
- - II 3G Ex nA nC e IIC T4